Key specifications:
| Specification | Value |
|---|---|
| Model | RXQ10BYM |
| Refrigerant type | R410a – Environmentally friendly |
| Mode | Cooling only |
| Cooling capacity | 95,500 Btu/h (~28.0 kW) |
| Power consumption | 6.41 kW |
| Dimensions (Height x Width x Depth) | 1,660 x 930 x 765 mm |
| Weight | 210 kg |
Daikin VRV A cooling-only outdoor unit, R410a refrigerant – Model RXQ10BYM | Powerful performance, energy efficient
Introducing the VRV A RXQ10BYM outdoor unit
The outdoor unit VRV A cooling-only, model RXQ10BYM is a premium product in Daikin's central air conditioning system range, known for powerful cooling, reliable operation and optimal energy efficiency. With a cooling capacity of up to 95,500 Btu/h (~28.0 kW), this unit is an ideal choice for commercial projects, office buildings, hotels or large shopping centers.
Key specifications
| Specification | Value |
|---|---|
| Model | RXQ10BYM |
| Refrigerant type | R410a – Environmentally friendly |
| Mode | Cooling only |
| Cooling capacity | 95,500 Btu/h (~28.0 kW) |
| Power consumption | 6.41 kW |
| Dimensions (Height x Width x Depth) | 1,660 x 930 x 765 mm |
| Weight | 210 kg |
Key advantages of the RXQ10BYM outdoor unit
-
✅ Energy saving: The outdoor unit uses advanced inverter technology to effectively reduce power consumption.
-
✅ Quiet and stable operation: With its optimized design and high-quality materials, the product minimizes operating noise.
-
✅ Compact design, easy installation: Its practical dimensions provide flexibility when choosing an installation space.
-
✅ Uses environmentally friendly R410a refrigerant: The refrigerant does not harm the ozone layer and meets modern environmental standards.
Practical applications
The outdoor unit Daikin VRV RXQ10BYM is suitable for a range of medium- and large-scale projects, such as:
-
Offices and high-rise buildings
-
Hotels, resorts and shopping centers
-
Hospitals, schools and factories
Why choose the VRV A RXQ10BYM outdoor unit?
-
? High reliability from the Daikin brand
-
? A smart, expandable central air conditioning system
-
? Long-term technical support and maintenance
Contact us now to get the best quote
If you are looking for an efficient, economical and sustainable cooling solution, don't overlook the VRV A RXQ10BYM outdoor unit. Contact us to get the best quote, technical support and advice on designing a system that meets your needs.
🔧 1. Preparation before installation
✅ Required tools and equipment:
-
Pressure gauge, clamp meter
-
Vacuum pump, copper pipe welding machine
-
Screw-tightening tools, torque wrench, adjustable wrench
-
Copper pipe meeting specifications (at least Type L)
-
Compliant electrical wiring (power cable, control cable)
-
Support base or mounting frame (if installing on a roof)
✅ Check that the installation location is suitable:
-
A level, sturdy surface that can support at least 300kg (the unit weighs 210kg)
-
Clearance requirements:
-
At least 300mm at the sides
-
At least 1,000mm at the front
-
Avoid direct sunlight and locations exposed to strong winds
-
🧱 2. Securing the outdoor unit
✅ Secure installation:
-
Place the outdoor unit on a mounting frame or concrete base with anti-vibration rubber pads.
-
Secure it firmly using expansion bolts or dedicated screws.
-
Ensure the unit is perfectly level to prevent vibration and compressor damage.
🌀 3. Connecting the copper pipes
✅ Copper pipe requirements:
-
Use the sizes specified by Daikin (refer to the technical manual for model RXQ10BYM)
-
Braze with nitrogen to prevent pipe oxidation
-
Insulate all refrigerant pipes (liquid and gas pipes)
✅ Pipe length and height difference:
-
Maximum total pipe length: approximately 165m (follow the technical catalogue)
-
Maximum height difference: 50m
-
Install an oil separator if the height difference exceeds 40m
⚡ 4. Electrical connection
✅ Power supply:
-
3-phase 380V - 50Hz power
-
Adequately rated power cable (minimum 4-6 mm²), with a grounding wire
-
A separate circuit breaker or CB for each outdoor unit
✅ Connect according to the wiring diagram:
-
Follow the manufacturer's wiring diagram
-
Use dedicated, shielded control cable
💨 5. Evacuation and refrigerant charging
✅ Evacuate the entire system:
-
Connect a gauge and vacuum pump to the service valve
-
Evacuate for at least 30 minutes or until the pressure is < -760mmHg
-
Check for leaks using soapy water spray or a refrigerant leak detector
✅ Charging with R410a refrigerant (if additional charge is required):
-
Calculate the refrigerant quantity based on the actual pipe length
-
Use the correct R410a refrigerant, charge in liquid form, do not charge in vapor form
-
Weigh the refrigerant using an electronic scale
🧪 6. Test run and inspection
-
Turn on the power CB and check that the voltage is stable
-
Start the system using the central controller
-
Check the current, refrigerant pressure, noise and vibration
-
Ensure that no errors are displayed and that the unit operates stably
📋 7. Handover and operating instructions
-
Provide the customer with technical guidance on operation and basic maintenance
-
Record the installation specifications: pipe length, refrigerant charge, electrical specifications
-
Provide the warranty certificate, installation log and technical documents
⚠️ Important notes
-
Installation must be carried out by a Daikin-certified or authorized technical contractor
-
Installation errors may result in loss of warranty, reduced performance or equipment damage
Would you like me to create a professional installation guide PDF or with illustrative diagrams of the piping, electrical connections and installation location?
Technical specifications
Customer reviews
Share your product feedback
Ratings and reviewsRelated Products
RXQ18BYM
RXQ16BYM
RXQ14BYM
RXQ12BYM
RXQ8BYM
Daikin VRV A Max 60HP RXQ60AMYMW Outdoor Unit - HRT
DAIKIN VRV A Max 58HP RXQ58AMYMW Outdoor Unit - HRT
DAIKIN VRV A Max 56HP RXQ56AMYMW Outdoor Unit - HRT
Sender information
- There are no products in the cart yet